Eaton

Eaton Distribution parts

رقم القطعة: 106211

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق Ohmva.

الوصف

Eaton Distribution parts

المواصفات

Ambient operating temperature - max40 °C
Ambient operating temperature - min-5 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78
FunctionsUninterrupted operation (Control mode) Low-voltage h.b.c. switch-fuse unit
Special featuresContinuous operation (rated operating mode)NH-fuse-links →#289998With clamp/screw connection setWithout fuse monitoringWith connection area coverMounting with snap-on mechanism
Product NameEaton Distribution parts
Catalog Number106211
Model CodeNH-SLS-00/160-60
EAN4015081059812
Product Length/Depth455 mm
Product Height136 mm
Product Width50 mm
Product Weight1.46 kg
CompliancesRoHS conform
Source URLhttps://www.eaton.com/gb/en-gb/skuPage.106211.html
Suitable forDouble T profile Triple T profile Combi-base for busbar mounting (12 - 30 mm) x 5/10 mm Combi-base for direct busbar mounting
Used with25 mm x 5/10 mm rail 15 mm x 5/10 mm rail 12 mm x 5/10 mm rail 20 mm x 5/10 mm rail 30 mm x 5/10 mm rail Triple T profile Double T profile 60 mm system Busbar fuse material
Type60 mm systemBusbar fuse material
Degree of protectionIP30 (operating state) IP30 IP10 (front cover open)
ModelFuse switch disconnector
Mounting positionVertical or horizontal
Number of polesThree-pole
Voltage rating at ACContacts: 500 / 400 V AC at AC-23BContacts: 690 V AC at AC-21BContacts: 690 V AC at AC-22B
Rated uninterrupted current (Iu)160 A
Rated operation current (Ie)160 A
Voltage rating400 V AC
Terminal capacity (stranded cable)1.5 mm² - 70 mm² (1x) at box terminal 70 mm² (1x) at flange connection
Frequency rating50 Hz - 60 Hz
Pollution degree3
Admissible heat dissipation (NH-SE) - max12 W
Fuse current rating at 500 V - max160 A
Heat dissipation at Ith AC without NH-SE20 W
Operating altitude without derating - max2000 mm
Rated insulation voltage (Ui)1000 V
Direction of incoming supplyAs required
Electrical connection type of main circuitRail connection
Overvoltage categoryIII
Frequency rating of contacts50 Hz - 60 Hz
Fuse current rating at 690 V - max160 A
Terminal capacity (cable)9 mm x 0.8 mm (6x) at box terminal
Frame00
Rated impulse withstand voltage (Uimp)8 kV
Lifespan, mechanical1400 operations
Lifespan, electrical200 operations
Rated conditional short-circuit current (Iq)50 kA 50 kA at AC (effective)
Construction size (fuse inserts)NH00
Rated operating voltage (Ue) at AC - max690 V
Rated operational current160 A (AC-21B) 125 A / 160 A (AC-23B) 160 A (AC-22B)
Screw diameter for flange connectionM8
Conventional thermal current Ith of auxiliary contacts (1-pole, open)160 A
Rated operational current (gL/gG) - max160 A
ConnectionTop or bottom
Distance between busbar centers60 mm
Release indicationNone
Distance between rail centers60 mm
Permitted heat loss from fuse links - max20 W at 160 A
Terminal capacity (copper busbar)Max. 20 mm x 8 mm for flat busbar at flange connection
Terminal capacity (copper band)9 mm x 0.8 mm (6x) at box terminal