| Ambient operating temperature - max | 40 °C |
|---|---|
| Ambient operating temperature - min | -5 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
| Functions | Uninterrupted operation (Control mode) Low-voltage h.b.c. switch-fuse unit |
| Special features | 100 millimeter between busbar centres, optionally with 185 mm adaptersContinuous operation (rated operating mode)With clamp/screw connection setWithout fuse monitoringWith connection area coverScrew fixing on busbar with drilled holes |
| Catalog Number | 106210 |
| Model Code | NH-SLS-00/160 |
| Product Length/Depth | 455 mm |
| Product Height | 120 mm |
|---|---|
| Product Width | 50 mm |
| Product Weight | 1.43 kg |
| Compliances | RoHS conform |
| Certifications | IEC/EN 60947-3 |
| Source URL | https://www.eaton.com/gb/en-gb/skuPage.106210.html |
| Used with | Z-…SAD 120 mm x 10 mm rail 40 mm x 10 mm rail Triple T profile 100 mm x 10 mm rail 60 mm x 10 mm rail Z-…SADD 50 mm x 10 mm rail 30 mm x 10 mm rail Double T profile 80 mm x 10 mm rail Busbar fuse material 185 mm system |
| Type | 185 mm systemBusbar fuse material |
| Degree of protection | IP30 (operating state) IP10 (front cover open) IP30 |
| Model | Fuse switch disconnector |
| Mounting position | Vertical or horizontal |
| Number of poles | Three-pole |
| Voltage rating at AC | Contacts: 500 / 400 V AC at AC-23BContacts: 690 V AC at AC-21BContacts: 690 V AC at AC-22B |
| Rated uninterrupted current (Iu) | 160 A |
| Rated operation current (Ie) | 160 A |
| Voltage rating | 400 V AC |
| Terminal capacity (stranded cable) | 70 mm² (1x) at flange connection 1.5 mm² - 70 mm² (1x) at box terminal |
| Frequency rating | 50 Hz - 60 Hz |
| Pollution degree | 3 |
| Admissible heat dissipation (NH-SE) - max | 12 W |
| Fuse current rating at 500 V - max | 160 A |
| Heat dissipation at Ith AC without NH-SE | 20 W |
| Operating altitude without derating - max | 2000 mm |
| Rated insulation voltage (Ui) | 1000 V |
| Direction of incoming supply | As required |
| Electrical connection type of main circuit | Rail connection |
| Overvoltage category | III |
| Frequency rating of contacts | 50 Hz - 60 Hz |
| Fuse current rating at 690 V - max | 160 A |
| Terminal capacity (cable) | 9 mm x 0.8 mm (6x) at box terminal |
| Frame | 00 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Lifespan, mechanical | 1400 operations |
| Lifespan, electrical | 200 operations |
| Rated conditional short-circuit current (Iq) | 50 kA at AC (effective) 50 kA |
| Construction size (fuse inserts) | NH00 |
| Rated operating voltage (Ue) at AC - max | 690 V |
| Rated operational current | 160 A (AC-21B) 125 A / 160 A (AC-23B) 160 A (AC-22B) |
| Screw diameter for flange connection | M8 |
| Conventional thermal current Ith of auxiliary contacts (1-pole, open) | 160 A |
| Rated operational current (gL/gG) - max | 160 A |
| Connection | Top or bottom |
| Distance between busbar centers | 100 mm |
| Release indication | None |
| Distance between rail centers | 100 mm 185 mm |
| Permitted heat loss from fuse links - max | 20 W at 160 A |
| Terminal capacity (copper busbar) | Max. 20 mm x 10 mm for flat busbar at flange connection |
| Terminal capacity (copper band) | 9 mm x 0.8 mm (6x) at box terminal |
| Screw connection for busbars | M8 Only in combination with adapter for … x 5/10 |