Eaton XV-152 Touch panel
رقم القطعة: 166704
لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.
يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.


رقم القطعة: 166704
لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.
يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.
Eaton XV-152 Touch panel
| Ambient operating temperature - max | 50 °C |
|---|---|
| Ambient operating temperature - min | 0 °C |
| Ambient storage temperature - max | 60 °C |
| Ambient storage temperature - min | -20 °C |
| Functions | Process default value (input) possible Process value representation (output) possible Additional software components, loadable SmartWire-DT coordination |
| Catalog Number | 166704 |
| Model Code | XV-152-E6-10TVRC-10 |
| Product Length/Depth | 345 mm |
| Product Height | 54 mm |
|---|---|
| Product Width | 260 mm |
| Product Weight | 2.95 kg |
| Certifications | IEC/EN 61000-6-2 Certified by UL for use in Canada IEC/EN 60950 EN 50178 CSA Class No.: none IEC/EN 61000-6-3 IEC/EN 61241-1 (ATEX 94/9/EG: Zone 22, Category 3D (II 3D Ex tc IIIC T70°C IP6x) UL 508 IEC/EN 61131-2, CE DNV GL UL 60950 UL Category Control No.: NRAQ UL File No.: E205091 CSA File No.: UL report applies to both US and Canada IEC/EN 61000-6-4 IEC/EN 61241-0 (ATEX 94/9/EG: Zone 22, Category 3D (II 3D Ex tc IIIC T70°C IP6x) cULus UL508 Security: UL EN 60950 ATEX 94/9/EG: Zone 22, Category 3D (II 3D Ex tc IIIC T70°C IP6x) CUL508 IEC/EN 60079-0 (ATEX 94/9/EG: Zone 22, Category 3D (II 3D Ex tc IIIC T70°C IP6x) IEC/EN 61131-2 |
| Source URL | https://www.eaton.com/gb/en-gb/skuPage.166704.html |
| Features | USB Host Slot for SD card Portrait format Target and web visualization Overload proof Fanless CPU and system cooling, natural convection-based passive cooling Ethernet interface USB device UL508, cUL approvals |
| Type | Coordinator for the SmartWire-DT communications system |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Please enquire |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Meets the product standard's requirements. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Degree of protection | IP20, rear NEMA 4X IP20 |
| Enclosure material | Metal, anodized |
| Built-in depth | 49 mm |
| Mounting method | Flush mounting - Clearance: Width x Height x Depth ≥ 30 mm (1.18") Flush mounting - Inclination from vertical: ±45° (if using natural convection) Flush mounting |
| Model | Metal enclosure and front plate |
| Fitted with: | SW interfaces 1 x Ethernet 10/100 Mbps (built-in interfaces) Numeric keyboard Alpha numeric keyboard Message indication 1 x USB device (built-in interface) 1 x CANopen®/easyNet (built-in interfaces) 1 x RS485 (built-in interface) Recipes Printer output Color display 1 x USB host 2.0 (built-in interface) Message system (incl. buffer and confirmation) 1 x SmartWire-DT (built-in interface) |
| Shock resistance | Mechanical, According to IEC/EN 60068-2-27 |
| Vibration resistance | According to IEC/EN 60068-2-6 |
| Operating temperature - max | 50 °C |
| Operating temperature - min | 0 °C |
| Equipment heat dissipation, current-dependent Pvid | 14.5 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0 W |
| Rated operational current for specified heat dissipation (In) | 0 A |
| Static heat dissipation, non-current-dependent Pvs | 14.5 W |
| Product category | SmartWire-DT coordinators |
| Connection to SmartWire-DT | Yes |
| Connection type | SWD: Plug, 8-pole Push in terminals, Supply voltage |
| Terminal capacity | 0.2 - 1.5 mm², solid 24 - 16 AWG, solid or stranded 0.25 - 1.5 mm², 24 - 16 AWG |
| Degree of protection (front side) | NEMA 4X IP65 |
| Voltage type | DC |
| Power consumption | 2.5 W (USB Slave to USB Host) 9.5 W total Max. 12 W 12 W |
| Rated operational current (Ie) | 0.7 A |
| Short-circuit protection | Yes, Short-circuit rating, SmartWire-DT supply voltage No, external fuse FAZ Z3, Supply voltage UAux |
| Explosion safety category for dust | ATEX dust-ex-protection, in relation to CE ATEX dust-ex-protection, II 3D Ex II T70°C IP5x: Zone 22, Category 3D |
| LED indicator | Status indication of Supply voltage: LED Status indication of SmartWire-DT master: Green and red LEDs Status indication of SmartWire-DT network: Configurable green or red LED |
| Connection | SmartWire-DT blade terminal SWD4-8MF2 |
| Memory capacity | 64,000 kByte |
| Memory | 64 MByte internal DRAM (OS, Program and data memory) NVRAM (Retain data): 125 kByte NAND-Flash (can be used for data backup): approx. 64 MByte available NOR-Flash: 2 MByte SD Memory Card Slot: SDA Specification 1.00 (External) |
| Relative humidity | 10 - 95 % (non-condensing) IEC/EN 50178 |
| Protocol | MODBUS TCP/IP EtherNet/IP Other bus systems CAN |
| Fuse type | Built-in fuse (not accessible) |
| Air pressure | 795 - 1080 hPa (operation) |
| Battery runtime | Back-up of real-time clock: CR 2032 (190 mA/h), zero maintenance (soldered) |
| Number of HW-interfaces (industrial ethernet) | 1 |
| Number of HW-interfaces (other) | 2 |
| Number of HW-interfaces (parallel) | 0 |
| Number of HW-interfaces (RS-232) | 0 |
| Number of HW-interfaces (RS-422) | 0 |
| Number of HW-interfaces (RS-485) | 1 |
| Number of HW-interfaces (USB) | 2 |
| Number of HW-interfaces (wireless) | 0 |
| Number of interfaces (PROFINET) | 0 |
| Protection against polarity reversal | Yes Yes, for supply voltage (Siemens MPI optional) |
| Data transfer rate | 250 kBit/s, SmartWire-DT 125 kBit/s, SmartWire-DT |
| Residual ripple | ≤ 5 % (input voltage) |
| Inrush current | 12.5 A (for 6 ms) |
| Processor | RISC CPU, 32 Bit, 400 MHz |
| Repetition rate | 1 s |
| Supply voltage at AC, 50 Hz - max | 0 VAC |
| Supply voltage at AC, 50 Hz - min | 0 VAC |
| Supply voltage at AC, 60 Hz - max | 0 VAC |
| Supply voltage at AC, 60 Hz - min | 0 VAC |
| Supply voltage at DC - max | 28.8 VDC |
| Supply voltage at DC - min | 20.4 VDC |
| Interfaces | CAN easyNet Ethernet (100Base-TX/10Base-T) USB 2.0 device (not galvanically isolated) RS485 |
| Potential isolation | Between UPow and 15 V SmartWire-DT supply voltage: no UAUX: no Power supply: no |
| Voltage dips | 5 ms from undervoltage (19.2 V DC) ≤ 10 ms from rated voltage (24 V DC) ≤ 10 ms, Bridging voltage dips |
| Width of the front | 345 mm |
| Resolution | 640 x 480 pxVGA |
| Display size | 211 x 158 mm |
| Backup time | 10 years, typ. (time at zero voltage) |
| Front height | 260 mm |
| Number of buttons (programmable function) | 0 |
| Number of buttons with LED | 0 |
| Number of grey-scales/blue-scales of display | 0 |
| Operating system | Windows CE 5.0 (license included) |
| Software | GALILEO, Visualization software, Engineering XSOFT-CODESYS-3, PLC-Programming software, Engineering EPAM, Visualization software, Engineering XSOFT-CODESYS-2, Visualization software, Engineering XSOFT-CODESYS-3, Visualization software, Engineering XSOFT-CODESYS-2, PLC-Programming software, Engineering |
| Display contrast ratio | 300:1 |
| Number of slots | 1 (for SD-Card) |
| Display lighting | Dimmable via software LED |
| Display type | Color display, TFT Standard front with standard membrane (fully enclosed) TFT |
| Lifespan | 40,000 h (Service life of back-lighting) |
| Rated control supply voltage | 24 V DC (UAUX, -20 %/+25 %) 24 V DC (UPOW, -20 %/+25 %) |
| Luminance intensity | 250 cd/m² |
| Number of colors of the display | 65536 |
| RoHs conformity | Yes |
| Touch technology | Resistive touch Glass with film touch sensor Touch sensor (glass with foil), Resistive touch protective screen |
| Number of HW-interfaces (serial TTY) | 0 |
| Number of online/runtime languages | 100 |
| Number of password levels | 200 |
| Number of pixels (horizontal) | 640 |
| Number of pixels (vertical) | 480 |
| Number of system buttons | 1 |
| Screen size (diagonal) | 10.4 in |
| Permissible voltage | 35 V DC (for a duration of < 100 ms) 19.2 - 30 V DC, effective (rated operating voltage -20 %/+25 %) 18 - 31.2 V DC, battery powered (rated operating voltage -25 %/+30 %) 18.0 - 31.2 V DC, absolute with ripple |
| Rated operational voltage | 24 V DC (power-supply - safety extra low voltage) Typically UAUX -0.2 V (for 24 V DC slaves) 14.5 V (± 3 % - SmartWire-DT) |
| Communication interface | SmartWire-DT master |
| Current consumption | 0.6 A, continuous current, Power Supply, 24 V DC |
| Supply current | 0.7 A, Imax, SmartWire-DT supply 3 A, Imax, Supply voltage UAux If SmartWire-DT modules with a total power consumption > 0.7 A are connected, a power feeder module EU5C-SWD-PF2 has to be used; SmartWire-DT supply If contactors with a total power consumption > 3 A are connected, a power feeder module EU5C-SWD-PF1/2 has to be used, Supply voltage UAux |
| Addressing | Address set automatically |
| Station | SmartWire-DT master, SmartWire-DT network |
| Number of SmartWire-DT slaves | 99 |