Eaton

Eaton XV-152 Touch panel

رقم القطعة: 166702

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع افتح تطبيق Ohmva.

الوصف

Eaton XV-152 Touch panel

المواصفات

Ambient operating temperature - max50 °C
Ambient operating temperature - min0 °C
Ambient storage temperature - max60 °C
Ambient storage temperature - min-20 °C
FunctionsProcess default value (input) possible Process value representation (output) possible SmartWire-DT coordination Additional software components, loadable
Product NameEaton XV-152 Touch panel
Catalog Number166702
Model CodeXV-152-E6-84TVRC-10
EAN7640130097728
Product Length/Depth275 mm
Product Height52.5 mm
Product Width208 mm
Product Weight2.15 kg
CertificationscULus CSA Class No.: none EN 60950 UL 508 CUL508 IEC/EN 61241-1 (ATEX 94/9/EG: Zone 22, Category 3D (II 3D Ex tc IIIC T70°C IP6x) IEC/EN 60950 UL EN 50178 IEC/EN 61131-2 ATEX 94/9/EG: Zone 22, Category 3D (II 3D Ex tc IIIC T70°C IP6x) UL508 Certified by UL for use in Canada UL Category Control No.: NRAQ CSA File No.: UL report applies to both US and Canada IEC/EN 61131-2, CE IEC/EN 61000-6-3 Security: IEC/EN 61000-6-4 IEC/EN 60079-0 (ATEX 94/9/EG: Zone 22, Category 3D (II 3D Ex tc IIIC T70°C IP6x) IEC/EN 61241-0 (ATEX 94/9/EG: Zone 22, Category 3D (II 3D Ex tc IIIC T70°C IP6x) UL 60950 IEC/EN 61000-6-2 UL File No.: E205091 DNV GL
Source URLhttps://www.eaton.com/gb/en-gb/skuPage.166702.html
FeaturesFanless CPU and system cooling, natural convection-based passive cooling Overload proof USB Host Target and web visualization Portrait format Slot for SD card Ethernet interface USB device UL508, cUL approvals
TypeCoordinator for the SmartWire-DT communications system
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationPlease enquire
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesMeets the product standard's requirements.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Degree of protectionIP20, rear NEMA 4X IP20
Enclosure materialMetal, anodized
Built-in depth47 mm
Mounting methodFlush mounting Flush mounting - Clearance: Width x Height x Depth ≥ 30 mm (1.18") Flush mounting - Inclination from vertical: ±45° (if using natural convection)
ModelMetal enclosure and front plate
Fitted with:Printer output 1 x RS485 (built-in interface) Numeric keyboard Message system (incl. buffer and confirmation) 1 x USB device (built-in interface) 1 x Ethernet 10/100 Mbps (built-in interfaces) 1 x USB host 2.0 (built-in interface) SW interfaces 1 x CANopen®/easyNet (built-in interfaces) Alpha numeric keyboard Message indication Recipes Color display 1 x SmartWire-DT (built-in interface)
Shock resistanceMechanical, According to IEC/EN 60068-2-27
Vibration resistanceAccording to IEC/EN 60068-2-6
Operating temperature - max50 °C
Operating temperature - min0 °C
Equipment heat dissipation, current-dependent Pvid14.5 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0 W
Rated operational current for specified heat dissipation (In)0 A
Static heat dissipation, non-current-dependent Pvs14.5 W
Product categorySmartWire-DT coordinators
Connection to SmartWire-DTYes
Connection typeSWD: Plug, 8-pole Push in terminals, Supply voltage
Terminal capacity0.25 - 1.5 mm², 24 - 16 AWG 0.2 - 1.5 mm², solid 24 - 16 AWG, solid or stranded
Degree of protection (front side)NEMA 4X IP65
Voltage typeDC
Power consumption2.5 W (USB Slave to USB Host) Max. 12 W 9.5 W total 12 W
Rated operational current (Ie)0.7 A
Short-circuit protectionNo, external fuse FAZ Z3, Supply voltage UAux Yes, Short-circuit rating, SmartWire-DT supply voltage
Explosion safety category for dustATEX dust-ex-protection, II 3D Ex II T70°C IP5x: Zone 22, Category 3D ATEX dust-ex-protection, in relation to CE
LED indicatorStatus indication of SmartWire-DT master: Green and red LEDs Status indication of SmartWire-DT network: Configurable green or red LED Status indication of Supply voltage: LED
ConnectionSmartWire-DT blade terminal SWD4-8MF2
Memory capacity64,000 kByte
MemoryNVRAM (Retain data): 125 kByte 64 MByte internal DRAM (OS, Program and data memory) SD Memory Card Slot: SDA Specification 1.00 (External) NAND-Flash (can be used for data backup): approx. 64 MByte available NOR-Flash: 2 MByte
Relative humidityIEC/EN 50178 10 - 95 % (non-condensing)
ProtocolMODBUS EtherNet/IP CAN TCP/IP Other bus systems
Fuse typeBuilt-in fuse (not accessible)
Air pressure795 - 1080 hPa (operation)
Battery runtimeBack-up of real-time clock: CR 2032 (190 mA/h), zero maintenance (soldered)
Number of HW-interfaces (industrial ethernet)1
Number of HW-interfaces (other)2
Number of HW-interfaces (parallel)0
Number of HW-interfaces (RS-232)0
Number of HW-interfaces (RS-422)0
Number of HW-interfaces (RS-485)1
Number of HW-interfaces (USB)2
Number of HW-interfaces (wireless)0
Number of interfaces (PROFINET)0
Protection against polarity reversalYes, for supply voltage (Siemens MPI optional) Yes
Data transfer rate250 kBit/s, SmartWire-DT 125 kBit/s, SmartWire-DT
Residual ripple≤ 5 % (input voltage)
Inrush current12.5 A (for 6 ms)
ProcessorRISC CPU, 32 Bit, 400 MHz
Repetition rate1 s
Supply voltage at AC, 50 Hz - max0 VAC
Supply voltage at AC, 50 Hz - min0 VAC
Supply voltage at AC, 60 Hz - max0 VAC
Supply voltage at AC, 60 Hz - min0 VAC
Supply voltage at DC - max28.8 VDC
Supply voltage at DC - min20.4 VDC
InterfacesEthernet (100Base-TX/10Base-T) easyNet CAN RS485 USB 2.0 device (not galvanically isolated)
Potential isolationBetween UPow and 15 V SmartWire-DT supply voltage: no Power supply: no UAUX: no
Voltage dips5 ms from undervoltage (19.2 V DC) ≤ 10 ms from rated voltage (24 V DC) ≤ 10 ms, Bridging voltage dips
Width of the front275 mm
Resolution640 x 480 pxVGA
Display size170 x 128 mm
Backup time10 years, typ. (time at zero voltage)
Front height208 mm
Number of buttons (programmable function)0
Number of buttons with LED0
Number of grey-scales/blue-scales of display0
Operating systemWindows CE 5.0 (license included)
SoftwareXSOFT-CODESYS-3, PLC-Programming software, Engineering XSOFT-CODESYS-2, Visualization software, Engineering XSOFT-CODESYS-3, Visualization software, Engineering EPAM, Visualization software, Engineering GALILEO, Visualization software, Engineering XSOFT-CODESYS-2, PLC-Programming software, Engineering
Display contrast ratio300:1
Number of slots1 (for SD-Card)
Display lightingDimmable via software LED
Display typeColor display, TFT Standard front with standard membrane (fully enclosed) TFT
Lifespan40,000 h (Service life of back-lighting)
Rated control supply voltage24 V DC (UPOW, -20 %/+25 %) 24 V DC (UAUX, -20 %/+25 %)
Luminance intensity250 cd/m²
Number of colors of the display65536
RoHs conformityYes
Touch technologyGlass with film touch sensor Touch sensor (glass with foil), Resistive touch protective screen Resistive touch
Number of HW-interfaces (serial TTY)0
Number of online/runtime languages100
Number of password levels200
Number of pixels (horizontal)640
Number of pixels (vertical)480
Number of system buttons1
Screen size (diagonal)8.4 in
Permissible voltage35 V DC (for a duration of < 100 ms) 18 - 31.2 V DC, battery powered (rated operating voltage -25 %/+30 %) 18.0 - 31.2 V DC, absolute with ripple 19.2 - 30 V DC, effective (rated operating voltage -20 %/+25 %)
Rated operational voltageTypically UAUX -0.2 V (for 24 V DC slaves) 24 V DC (power-supply - safety extra low voltage) 14.5 V (± 3 % - SmartWire-DT)
Communication interfaceSmartWire-DT master
Current consumption0.6 A, continuous current, Power Supply, 24 V DC
Supply current0.7 A, Imax, SmartWire-DT supply If contactors with a total power consumption > 3 A are connected, a power feeder module EU5C-SWD-PF1/2 has to be used, Supply voltage UAux 3 A, Imax, Supply voltage UAux If SmartWire-DT modules with a total power consumption > 0.7 A are connected, a power feeder module EU5C-SWD-PF2 has to be used; SmartWire-DT supply
AddressingAddress set automatically
StationSmartWire-DT master, SmartWire-DT network
Number of SmartWire-DT slaves99