Discovery Optical Smoke Detector [SIL2]
رقم القطعة: 58000-600SIL
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق Ohmva.
رقم القطعة: 58000-600SIL
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق Ohmva.
The Discovery Optical Smoke Detector are high-specification devices using the light scatter principle to quickly detect fire while effectively managing false alarms. Reliable fire detection in areas with a very wide temperature range from -40°C to +70°C Five operating modes suitable for a range of applications where unique response behaviour is required Drift compensation to ensure constant sensitivity Ideal for accommodation dbimecks, passages and escape routes Assessed and certified for use in a safety function to SIL level 2
| General / Warranty | 10 year |
|---|---|
| Mechanical / Product length | 42mm |
| Conformance / Approvals | LPCB, ESC, CPR |
| Mechanical / Product length (imperial) | 1.65in |
| Mechanical / Weight | 105g |
| Mechanical / Materials housing | Polycarbonate |
| Mechanical / Product diameter | 100mm |
| Environmental / Operating temperature (max) | 70°C |
| Environmental / Operating temperature (min) | -40°C |
| Environmental / Operating temperature | -40 to 70°C |
| Conformance / Standards | EN 54-7 |
| Electrical / Supply voltage (min) | 17V dc |
| Environmental / Operating temperature (imperial) | -40 to 158°F |
| Electrical / Supply voltage (max) | 28V dc |
| Environmental / Operating temperature (max) (imperial) | 158°F |
| Electrical / Supply voltage (Vmin-Vmax) | 17 to 28V dc |
| Environmental / Operating temperature (min) (imperial) | -40°F |
| Mechanical / Product diameter (imperial) | 3.94in |
| Environmental / Humidity (max) | 95%, RH |
| General / Applications | Bedrooms, Escape routes, Hospitals, Hotels, Medium to large buildings, Offices, University campuses, Restaurants |
| Environmental / Humidity (min) | 0%, RH |
| Environmental / Humidity Note | no condensation or icing |
| Electrical / Protocol voltage | 5 to 9V peak to peak |
| Environmental / Humidity | 0% to 95% (no condensation or icing) |
| Electrical / Protocol voltage (max) | 9V |
| Electrical / Protocol voltage (min) | 5V |
| Mechanical / Detection principle | Photo-electric light scattering. |
| Electrical / Polarity | L1 &, L2 are polarity insensitive |
| Mechanical / Materials terminals | Nickel plated stainless steel |
| Electrical / Power-up surge current | 1mA |
| Electrical / Quiescent current | 440μA |
| Electrical / Quiescent current tested at | 24V dc |
| Electrical / Terminal functions +R | +R, Remote indicator positive connection |
| Electrical / Terminal functions -R | -R, Remote indicator negative connection |
| Performance / Chamber type | Chevron |
| General / Fire Type | Slow burning, smouldering fires |
| Electrical / Status indicator – Alarm | Red |
| Electrical / Sampling frequency | Once per second |
| Performance / Analogue value nominal | 23 |
| Performance / Analogue value (- tolerance) | 0 |
| Performance / Analogue value (+ tolerance) | 4 |
| Performance / Analogue value | 23 +4/-0 |
| Performance / Alarm level analogue value | 55 |
| Apollo Part Number | 58000-600SIL |
| Apollo Range | discovery |
| Apollo Category | detector |