| Basic information / Model name | QS0J61BT12 |
|---|---|
| Basic information / Overview | CC-Link Safety manager station |
| Basic information / Sales status | Discontinued |
| Listed / Model name | QS0J61BT12 2023/09 Discontinued |
| Weight | 0.12 kg |
| Basic information / Conformance standard | UL cUL CE(EMC) CE(Machinery) CE(RoHS) IEC 61508 IEC 62061 EN ISO 13849-1 KC(EMC) |
| Basic information / End of order date | 2023/06 |
| Basic information / Discontinued date | 2023/09*Please check or inquire it in each overseas sales company site because the sale situation is different depending on each countries. |
| Basic information / Replacement models | RJ71GN11-T2 Learn more about our products Compare replacement models and specifications |
|---|---|
| Basic information / Repair support expiration date | 2030/09 |
| Number of occupied I/O points | 32 points (I/O assignment: Intelligent 32 points) |
| Transmission speed | 156 kbps/625 kbps/2.5 Mbps/5 Mbps/10 Mbps (selectable) |
| Network topology | Bus (RS-485) |
| Communication method | Broadcast polling method |
| Listed / Outline | CC-Link Safety manager station |
| Internal current consumption (5 V DC) | 0.46 A |
| Listed / Large categories | Safety network |
| Listed / Medium categories | CC-Link Safety |
| General specifications | Refer to the general specifications of the CPU module. |
| Synchronization method | Frame synchronization method |
| Communication cable | Ver.1.10 compatible CC-Link dedicated cable CC-Link dedicated cable (Ver.1.00 compatible) CC-Link dedicated high-performance cable (Ver.1.00 compatible) |
| Encoding method | NRZI method |
| Station type | Safety manager station |
| Listed / Small categories | Manager station |
| Maximum overall cable distance (Maximum transmission distance) / Ver. 1.10 / 156 kbps | 1200 m |
| Maximum overall cable distance (Maximum transmission distance) / Ver. 1.10 / 625 kbps | 900 m |
| Maximum overall cable distance (Maximum transmission distance) / Ver. 1.10 / 2.5 Mbps | 400 m |
| Maximum overall cable distance (Maximum transmission distance) / Ver. 1.10 / 5 Mbps | 160 m |
| Maximum overall cable distance (Maximum transmission distance) / Ver. 1.10 / 10 Mbps | 100 m |
| Maximum number of connected stations | 64 |
| Maximum number of link points per system | Remote I/O (RX, RY) : 2048 points Remote register (RWw) : 256 points Remote register (RWr) : 256 points |
| Link points per remote station / Safe .. ion / Number of occupied stations: 1 station ~e2ba1a | Remote input (RX) : 32 points Remote output (RY) : 32 points Remote register (RWw) : 0 points Remote register (RWr) : 0 points |
| Link points per remote station / Stan .. ion / Number of occupied stations: 1 station ~1b5913 | Remote input (RX) : 32 points Remote output (RY) : 32 points Remote register (RWw) : 4 points Remote register (RWr) : 4 points |
| Link points per remote station / Stan .. on / Number of occupied stations: 2 stations ~746615 | Remote input (RX) : 64 points Remote output (RY) : 64 points Remote register (RWw) : 8 points Remote register (RWr) : 8 points |
| Link points per remote station / Stan .. on / Number of occupied stations: 3 stations ~f8b8b4 | Remote input (RX) : 96 points Remote output (RY) : 96 points Remote register (RWw) : 12 points Remote register (RWr) : 12 points |
| Link points per remote station / Stan .. on / Number of occupied stations: 4 stations ~388e13 | Remote input (RX) : 128 points Remote output (RY) : 128 points Remote register (RWw) : 16 points Remote register (RWr) : 16 points |
| Transmission format | HDLC compliant |
| Error control system / Safety remote I/O station | CRC32 (X32 + X26 + X23 + X22 + X16 + X12 + X11 + X10 + X8 + X7 + X5 + X4 + X2 + X + 1) |
| Error control system / Standard remote I/O station | CRC16 (X16 + X12 + X5 + 1) |