Simplex

TrueAlarm Multi-Sensor Smoke Detector

رقم القطعة: 4098-9754

لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.

يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.

الوصف

TrueAlarm Multi-Sensor Smoke Detector

المواصفات

Simplex Product ClassAccessories; Detection Devices; Enclosures and Mounting; Fire Control Panels; Modules and Interfaces; Networking and Integration; Notification Appliances; User Interfaces
Simplex SubcategoryAddressable Fire Control Units; Addressable Heat Detectors; Addressable Multi-Sensor Detectors; Addressable Smoke Detectors; Addressable Sounder Bases; Control Panel Boards and CPUs; Control Panel CPUs and Core Processing; Detector Bases; LED Modules; Miscellaneous; Mounting Devices And Kits; Network Controllers; Network Display Units; Network Interface Modules; Protective Covers; Relay Modules; Zone Adapter Modules
Simplex CategoryAddressable fire alarm control unit; Alarm Device; CO sensor base; Enclosure; Fire alarm network; Heat sensor; Individual addressable module; Network annunciator; Network interface; Pull station; Sensor base; Smoke detector; Sounder base
DescriptionPhoto/Heat Multi-Sensor
Additional detailThree: one for photo, one for heat, one for CO
Compatibility4007ES, 4010ES, 4100ES, and 4100U IDNet. Uses only one address. Use with the following sensor bases: 4098-9770, 4098-9771, 4098-9780, 4098-9789, 4098-9791, 4098-9792, 4098-9793, 4098-9775, 4098-9776, 4098-9777, 4098-9794 4098-9797, 4098-9798 4098-9766, 4098-9767, IDNet2 only
4100-3102 MAPNET II moduleYes
Software revision requirementsUse with 4100U requires revision 11.0 software or higher.
كل المواصفات (21)
Point typeMCOPHS
Public points usageUp to six: one for trouble reporting, one for photo (MPHOTO), one for heat (MHEAT), one for CO gas (MCOGAS), one for CO fire (MACOFIRE), one to select multi-point correlation: false alarm reduction (MACOFALSE), or faster detection (MACOFAST), or correlation off (MAOFF)
Panel I/O point usageOne
I/O point usageUp to seven: one for trouble reporting, one for sounder (MSOUND), one for photo (MPHOTO), one for heat (MHEAT) one for CO gas (MCOGAS), one for CO fire (MACOFIRE), one to select multi-point correlation: false alarm reduction (MACOFALSE), or faster detection (MACOFAST), or correlation off (MAOFF)
Specifications / Humidity Range10 to 95% RH
Specifications / UL Listed Temperature Range32° F to 100° F (0° C to 38° C)
Specifications / Operating Temperature Range15° F to 122° F (-9° C to 50° C)
Specifications / Alarm Current13 mA from separate 24 VDC supply
Specifications / Relay size2-1/2" X 1-1/2" X 1"
Specifications / Sounder Voltage18 to 32 VDC from steady external source or from NAC
Specifications / Alarm Current (Sounder On)20 mA @ 24 VDC, 24 mA maximum @ 32 VDC
Specifications / Storage Temperature Range0° F to 140° F (-18° C to 60° C)
Specifications / Smoke Sensor Air Velocity Range0-4000 ft/min (0-1220 m/min)