Category 5e Cable, 4 Pair, SF/UTP, LSZH Indoor 60332-3-25
رقم القطعة: 1633NHC
لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.
يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.
رقم القطعة: 1633NHC
لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.
يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.
Category 5e Cable, 4 Pair, SF/UTP, LSZH Indoor 60332-3-25
| Update and Revision | Revision Number: 0.288 Revision Date: 02-20-2026 |
|---|---|
| Source URL | https://www.belden.com/products/cable/ethernet-cable/category-5e-cable/1633nhc |
| Belden Taxonomy Path | cable > ethernet-cable > category-5e-cable |
| Belden Category | cable |
| Belden Subcategory | ethernet-cable |
| Belden Sub-subcategory | category-5e-cable |
| CEC / C(UL) Compliance | . |
| Frequency | Max. Transfer Impedance |
| Suitable Applications | Horizontal and building backbone cable; Support current and future Category 5e applications, such as: 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM |
|---|---|
| Max. Pull Tension | 80 N (18 lbf) |
| Bulk Cable Weight | 43 kg/km |
| Environmental Suitability | Indoor |
| Flammability / Reaction to Fire | IEC 60332-3-25 |
| European Directive Compliance | EU CE Mark |
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. |
| RoHS Document URL | https://catalog.belden.com/assets/docs/1633NHC_rohs.pdf |
| UK Regulation Compliance | UKCA Mark |
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 6.3 mm (0.25 in) |
| CENELEC Compliance | EN 50173-1, Segregation class according EN50174-2 = c |
| European Halogen Free Standards | IEC 60754-1 - Halogen Amount = Zero |
| Outer Shield Table Notes | Aluminum facing outside in contact with drain wire |
| Overall Cable Diameter (Nominal) | 6.3 mm (0.25 in) |
| Stationary Min. | Installation Min. |
| Material | Nom. Diameter |
| Operating | Installation |
| Max. Delay Skew | Nom. Velocity of Prop. |
| High Frequency Table Notes | Limits below 4 MHz are for information only. Reference standard: IEC 61156-5 |
| Transfer Impedance Class | Grade 2 |
| Screening Class | Type II |
| Screening Table Notes | Coupling Attenuation |
| IEEE Compliance | PoE: IEEE 802.3bt Type 1, Type 2, Type 3 |
| Data Category | Category 5e |
| TIA/EIA Compliance | ANSI/TIA 568.2-D |
| ISO/IEC Compliance | ISO/IEC 11801-1 |
| -30°C to +60°C | 0°C To +50°C |
| Datasheet URL | https://catalog.belden.com/techdata/EN/1633NHC_techdata.pdf |
Belden
اطلب عرض سعر

Belden
اطلب عرض سعر
Belden
اطلب عرض سعر
Belden
اطلب عرض سعر
Belden
اطلب عرض سعر
Belden
اطلب عرض سعر

Belden
اطلب عرض سعر

Belden
اطلب عرض سعر