Generator Rotor Protection Relay: MRR1

المواصفات

DownloadDownload Brochure <!--
Feature 1Detection of high impedance earth faults with a low frequency test voltage.
Feature 2Short circuit and overvoltage-proof measuring input for the earth fault protection
Feature 3Exciter current measurement galvanically isolated, measuring range 0-20A
Feature 4Display of insulation resistance and of the excitation current
Feature 5Excitation current over & undercurrent protection with independent settings for current and delay time
Feature 6Detection of diode failures by supervision of the ripple component of the excitation current
Feature 7Two-stage supervision of the rotor insulation resistance with independent settings for resistance and time delay
كل المواصفات (36)
Feature 8Digital inputs for blocking and for remote reset
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/special-function-relay/generator-rotor-protection-relay-mrr1/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > special-function-relay > generator-rotor-protection-relay-mrr1
C&S Categoryprotectionandmeasurementdevices
BenefitsMultifunction Generator Rotor Protection Relay MRR1 provides comprehensive protection by integrating multiple functions into one device, which enhances system reliability, reduces downtime, and simplifies maintenance. Combination of several crucial protections in a single compact unit (MRR1 combines rotor earth fault, excitation over/undercurrent, and rotating diode failure protection). The relay prevents severe damage to the generator by detecting and isolating faults and abnormal conditions quickly (such as voltage fluctuations, overloads, and earth faults), thereby extending its operational life. The relay’s fast and selective tripping action ensures only the faulty section is isolated, minimising disruption to the rest of the system and enabling quick fault isolation. The device stores detailed information about fault events with date and time stamps, and may include disturbance recording. Integrating multiple functions into one device reduces the need for separate relays, saving panel space and potentially lowering installation and inventory costs. Modern C&S relays often include communication ports and other monitoring systems, allowing for remote operation and control.
Feature 9Programmable function of the blocking input
Feature 10Programmable assignment of protective functions to output relays
Feature 11Remote interfacing via RS-485 (optional)
Feature 12Introduction
Feature 13Benefits
Feature 14Contact Our Experts
Feature 15Download
Feature 16DC undercurrent relay
Feature 17Field relay
Feature 18Rectification failure relay
Feature 19Ground detector relay
Feature 20DC overcurrent relay
Feature 21Combination of several crucial protections in a single compact unit (MRR1 combines rotor earth fault, excitation over/undercurrent, and rotating diode failure protection).
SummaryFDC1 V5 relay offers numerical protection, fault logging, programmable voltage thresholds and LCD monitoring for DC systems. Explore specifications and configuration details.
Feature 22The relay prevents severe damage to the generator by detecting and isolating faults and abnormal conditions quickly (such as voltage fluctuations, overloads, and earth faults), thereby extending its operational life.
Feature 23The relay’s fast and selective tripping action ensures only the faulty section is isolated, minimising disruption to the rest of the system and enabling quick fault isolation.
C&S Subcategoryspecial-function-relay
Feature 24The device stores detailed information about fault events with date and time stamps, and may include disturbance recording.
Feature 25Integrating multiple functions into one device reduces the need for separate relays, saving panel space and potentially lowering installation and inventory costs.
Feature 26Modern C&S relays often include communication ports and other monitoring systems, allowing for remote operation and control.
IntroductionThe generator rotor protection relay MRR1 combines rotor earth fault protection, excitation over- and under-current protection. Thus providing a powerful protection regarding the rotor of synchronous generators. DC undercurrent relay Field relay Rectification failure relay Ground detector relay DC overcurrent relay The rotor earth fault element detects high- and low-resistance earth faults of the rotor winding. It is equipped with two stages, one for alarm, one for trip. The protective functions are: Undercurrent, overcurrent and ripple detection for diode failure protection. Because of the combination of three protective functions in one device, the MRN2 is a very compact mains de-coupling device.
Generator Rotor Protection Relay: MRR1FEATURES Detection of high impedance earth faults with a low frequency test voltage. Short circuit and overvoltage-proof measuring input for the earth fault protection Exciter current measurement galvanically isolated, measuring range 0-20A Display of insulation resistance and of the excitation current Excitation current over & undercurrent protection with independent settings for current and delay time Detection of diode failures by supervision of the ripple component of the excitation current Two-stage supervision of the rotor insulation resistance with independent settings for resistance and time delay Digital inputs for blocking and for remote reset Programmable function of the blocking input Programmable assignment of protective functions to output relays Remote interfacing via RS-485 (optional) Introduction Benefits Contact Our Experts Download The generator rotor protection relay MRR1 combines rotor earth fault protection, excitation over- and under-current protection. Thus providing a powerful protection regarding the rotor of synchronous generators. DC undercurrent relay Field relay Rectification failure relay Ground detector relay DC overcurrent relay The rotor earth fault element detects high- and low-resistance earth faults of the rotor winding. It is equipped with two stages, one for alarm, one for trip. The protective functions are: Undercurrent, overcurrent and ripple detection for diode failure protection. Because of the combination of three protective functions in one device, the MRN2 is a very compact mains de-coupling device. Multifunction Generator Rotor Protection Relay MRR1 provides comprehensive protection by integrating multiple functions into one device, which enhances system reliability, reduces downtime, and simplifies maintenance. Combination of several crucial protections in a single compact unit (MRR1 combines rotor earth fault, excitation over/undercurrent, and rotating diode failure protection). The relay prevents severe damage to the generator by detecting and isolating faults and abnormal conditions quickly (such as voltage fluctuations, overloads, and earth faults), thereby extending its operational life. The relay’s fast and selective tripping action ensures only the faulty section is isolated, minimising disruption to the rest of the system and enabling quick fault isolation. The device stores detailed information about fault events with date and time stamps, and may include disturbance recording. Integrating multiple functions into one device reduces the need for separate relays, saving panel space and potentially lowering installation and inventory costs. Modern C&S relays often include communication ports and other monitoring systems, allowing for remote operation and control. <input type="hidden" name="_wpcf7cf_options" value="{"form_id":84938,"conditions":[],"settings":{"animation":"yes","animation_intime":200,"animation_outtime":200,"conditions_ui":"normal","notice_dismissed":false,"repeater_remove_button&
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2025/11/MRR1-Generator-Rotor-Protection-Relay.pdf

السعر عند الطلب

اطلب عرض سعر