CSFPI-C3 Earth Fault Passage Indicator

رقم القطعة: CS-CSFPI-C3-EARTH-FAULT-PASSAGE-INDICATOR-2

لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.

يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.

الوصف

CSFPI-C3 Earth Fault Passage Indicator

المواصفات

Feature 1Earth-Fault Trip Current (Phase to Ground): Adjustable: 100 / 130 / 160 / 180 /200 /240 /300 A (110%) **
Feature 2Earth Fault Response Time: Adjustable 30 / 60 / 80/ 100 ms (i100rnSec)
Feature 3Indication Unit: Suitable for panel installation
Feature 4Programmable Earth fault pickup level (wide range 100A to 300A)
Feature 5Indication of earth—fault by blinking of Earth—tault LED
Feature 6Programmable response delay for Earth-fault
Feature 7Up-to Two potential free contacts to indicate earth»fault. (remote indication for SCADA)
Feature 8Various Reset option for Fault Reset
كل المواصفات (24)
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/fpi/csfpi-c3-earth-fault-passage-indicator-2/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > fpi > csfpi-c3-earth-fault-passage-indicator-2
C&S Categoryprotectionandmeasurementdevices
PresentationCSFPI, Fault Passage Indicator — Earth is designed to detect and indicate Earth fault on a cable system, in RMU networks with one input / open ring arrangement. The unit will indicate a fault condition when current is detected above set trip current settings. Fault current is sensed by cable mounted sensor, which gives signal to indication unit. Sensor must be mounted on screened cable and can be retrofitted on the cable.
Download BrochureDownload Brochure <!--
Feature 9Self Reset in the event of momentary fault (By monitoring current after a fault)
Feature 10Reset through Potential free input & AC/DC voltage recovery
Feature 11Reset manually by push button
Feature 12Reset automatically by a field configurable timer (hour)
Feature 13Presentation
Feature 14Contact Our Experts
Feature 15Download Brochure
SummaryEnsure reliable fault detection with the CSFPI-C3 Earth Fault Passage Indicator from C&S Electric. View specs & connect with our experts now.
C&S Subcategoryfpi
CSFPI-C3 Earth Fault Passage IndicatorRANGE Earth-Fault Trip Current (Phase to Ground): Adjustable: 100 / 130 / 160 / 180 /200 /240 /300 A (110%) ** Earth Fault Response Time: Adjustable 30 / 60 / 80/ 100 ms (i100rnSec) Indication Unit: Suitable for panel installation FEATURES Programmable Earth fault pickup level (wide range 100A to 300A) Indication of earth—fault by blinking of Earth—tault LED Programmable response delay for Earth-fault Up-to Two potential free contacts to indicate earth»fault. (remote indication for SCADA) Various Reset option for Fault Reset Self Reset in the event of momentary fault (By monitoring current after a fault) Reset through Potential free input & AC/DC voltage recovery Reset manually by push button Reset automatically by a field configurable timer (hour) Presentation Contact Our Experts Download Brochure CSFPI, Fault Passage Indicator — Earth is designed to detect and indicate Earth fault on a cable system, in RMU networks with one input / open ring arrangement. The unit will indicate a fault condition when current is detected above set trip current settings. Fault current is sensed by cable mounted sensor, which gives signal to indication unit. Sensor must be mounted on screened cable and can be retrofitted on the cable. <input size="40" maxlength="400" class="wpcf7-form-control wpcf7-text wpcf7-validates-as-required l
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2016/04/CSEPRO-T170-Catalogue.pdf