C&S Electric

Intelligent Motor Controller (with communication)

رقم القطعة: CS-EMPR

لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.

يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.

الوصف

Intelligent Motor Controller (with communication)

المواصفات

Feature 1Over load, Under load, Reverse phase, Phase loss, Locked rotor, Unbalance, E/F protection function
Feature 2Current range 0.125A~60A within one device
Feature 3Different functions selectable within one device, e.g Direct starter, Reversing starter, Y-D starter, Reactor / Inverter starter
Feature 4MCC, Local, Auto, Water level, Remote control
Feature 5Instantaneous under voltage compensation, Auto re-starter function
Feature 6Fault analysis, Fault value storing(Fault recording)
Feature 7Total operating time recording, Setting function Modbus, RS-485 / RS – 422 port
Feature 8Digital Relay with built-in MCU (Micro Processor Control Unit).
كل المواصفات (61)
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/empr/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > empr
C&S Categoryprotectionandmeasurementdevices
PresentationPrevent Motor Failure Increase Motor Life Reduced Down Time – Improve Productivity Reduce Inventory – Common Model Improve Productivity-Overload Alarm Before Trip Long Life – Maintains Accuracy of Settings Earth Fault Protection – Trip Only The Faulted Motor and not the Incoming Supply
Download BrochureDownload Brochure <!--
Feature 9Multiple protection: Over load / Phase failure / Stall /Asymmetry / Phase reverse/ Earth Fault.
Feature 10Current setting 0.5-6A & 5-60A. Current setting 0.5-6A can be used upto 600A with external Ct’s
Feature 11Fault diagnostic seven segment display of fault & values.
Feature 12Digital Ammeter function.
Feature 13Time setting : Inverse time (0-60 sec), Definite time (0-60 sec) starting & Delay time (0-30 sec) operating time.
Feature 14Accuracy : Current / Time + 5% of setting.
Feature 15Fail safe operation
Feature 16Alert function (60-110% of set current).
Feature 17Inverse / Definite time characteristics, site selectable.
Feature 18C.T. ratio setting in CSMPM-06 frame only.
Feature 19Multiple protection: Over load / Phase failure / Stall /Asymmetry / Phase reverse.
Feature 20Current setting upto 80A in 3 frame sizes.
Feature 21Fault diagnose by LEDs indication.
SummaryProtect motors with C&S Electronic Motor Protection Relays multi-function, 0.125–60A range, fault recording & Modbus ready. Ensure reliability download now!
Feature 22Time setting 0 – 30 sec.
Feature 23Accuracy : Current / Time + 5%.
C&S Subcategoryempr
Feature 24Relays with built-in MCU (Micro Processor Control Unit)
Feature 25Environment operational temperature (-25 C to +70 C).
Feature 26Compact design & Elegant outlook.
Feature 27Common use of the Screw type & Tunnel type.
Feature 28Applicable to the inverter circuit (20 – 200 Hz).
Feature 29Mounting options : 35mm Din-rail or Screw.
Feature 30Fail safe operation.
Feature 31Protection : Over load & phase failure
Feature 32Time setting : Starting time (0.2-30 sec), Operating time(0.2-15 sec)
Feature 33Accuracy : Current/Time + 5% / (+0.5 sec)
Feature 34Compact Size, Economical
Feature 35Relays with built-in MCU (Micro Processor Control Unit)
Feature 36Current setting: 0.5-6A or 5-60A options. Current setting 0.5-6A can be used upto 600A with external CT’s
Feature 37Looping option is available for FHP Motors
Feature 38Fault diagnostic by LED indication
Feature 39Mounting option: 35mm Din-rail or Screw
Feature 40Presentation
Feature 41Contact Our Experts
Feature 42Download Brochure
Feature 43Prevent Motor Failure
Feature 44Increase Motor Life
Feature 45Reduced Down Time – Improve Productivity
Feature 46Reduce Inventory – Common Model
Feature 47Improve Productivity-Overload Alarm Before Trip
Feature 48Long Life – Maintains Accuracy of Settings
Feature 49Earth Fault Protection – Trip Only The Faulted Motor and not the Incoming Supply
Intelligent Motor Controller (with communication)FEATURES Over load, Under load, Reverse phase, Phase loss, Locked rotor, Unbalance, E/F protection function Current range 0.125A~60A within one device Different functions selectable within one device, e.g Direct starter, Reversing starter, Y-D starter, Reactor / Inverter starter MCC, Local, Auto, Water level, Remote control Instantaneous under voltage compensation, Auto re-starter function Fault analysis, Fault value storing(Fault recording) Total operating time recording, Setting function Modbus, RS-485 / RS – 422 port
CSMPM - Digital RelaysFEATURES Digital Relay with built-in MCU (Micro Processor Control Unit). Multiple protection: Over load / Phase failure / Stall /Asymmetry / Phase reverse/ Earth Fault. Current setting 0.5-6A & 5-60A. Current setting 0.5-6A can be used upto 600A with external Ct’s Fault diagnostic seven segment display of fault & values. Digital Ammeter function. Time setting : Inverse time (0-60 sec), Definite time (0-60 sec) starting & Delay time (0-30 sec) operating time. Accuracy : Current / Time + 5% of setting. Fail safe operation Alert function (60-110% of set current). Inverse / Definite time characteristics, site selectable. C.T. ratio setting in CSMPM-06 frame only.
CSMPA - Analog Relays (CSMPA22/40/80)Features Inverse Time Characteristics Multiple protection: Over load / Phase failure / Stall /Asymmetry / Phase reverse. Current setting upto 80A in 3 frame sizes. Fault diagnose by LEDs indication. Time setting 0 – 30 sec. Accuracy : Current / Time + 5%. Relays with built-in MCU (Micro Processor Control Unit) Environment operational temperature (-25 C to +70 C). Compact design & Elegant outlook. Common use of the Screw type & Tunnel type. Applicable to the inverter circuit (20 – 200 Hz). Mounting options : 35mm Din-rail or Screw. Fail safe operation.
CSMPA - Analog Relays (CSMPA 60T)Features Definite Time Characteristics Protection : Over load & phase failure Time setting : Starting time (0.2-30 sec), Operating time(0.2-15 sec) Accuracy : Current/Time + 5% / (+0.5 sec) Compact Size, Economical Relays with built-in MCU (Micro Processor Control Unit) Current setting: 0.5-6A or 5-60A options. Current setting 0.5-6A can be used upto 600A with external CT’s Looping option is available for FHP Motors Fault diagnostic by LED indication Mounting option: 35mm Din-rail or Screw Presentation Contact Our Experts Download Brochure Prevent Motor Failure Increase Motor Life Reduced Down Time – Improve Productivity Reduce Inventory – Common Model Improve Productivity-Overload Alarm Before Trip Long Life – Maintains Accuracy of Settings Earth Fault Protection – Trip Only The Faulted Motor and not the Incoming Supply <span class="wpcf7-form-control-wrap recaptcha" data-name="rec
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2016/03/EMPR-catalogue.pdf

السعر عند الطلب

اطلب عرض سعر