C&S Electric

Full Featured AMF relay with 3 Phase CT Sensing : EGA-250

رقم القطعة: CS-EGA-250-AUTO-MAINS-FAILURE-RELAY

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق Ohmva.

الوصف

Full Featured AMF relay with 3 Phase CT Sensing : EGA-250

المواصفات

DownloadDownload Brochure <!--
Feature 1Display of 3 Phase Mains Parameters: Voltage and Frequency
Feature 2Display of 3 Phase Generator Parameters: Voltage, Frequency, Speed, Run Hours
Feature 3Metering Energy for both Mains& DG
Feature 4Wide range of Analog Sensor Selection
Feature 5All DI/DOs are programmable
Feature 6Presentation
Feature 7Benefits
Feature 8Contact Our Experts
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/amf-relays/ega-250-auto-mains-failure-relay/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > amf-relays > ega-250-auto-mains-failure-relay
C&S Categoryprotectionandmeasurementdevices
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2016/05/EGA-250-Catalogue.pdf
PresentationEGA-250 is a AUTOMATIC/MANUAL Generator controller module including protection for standby power supply (Generatorl DG Set). It uses single advanced micro controller chip for an easy and trouble free DG control. It is cost effective solution for AMF controlling system. If mains voltage in any phase fails (either voltage or frequency goes out of the selected range) EGA-250 initiates an automatic DG start cycle including load transfer by switching the contactors mounted in the panel. After the mains is restored the load will be automatically removed from DG and transferred to mains. DG will stop after a set cool down time. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal DG conditions are detected and displayed on LCD display and if necessary DG is stopped and hooter gets activated. Automatic Mode:This mode is selectable from parameter settings. User can toggle between Auto Mode and Manual/Remote Mode from DI also.ln this mode of operation, if the mains either fail or exceed operating limits GEN-SET is started, mains CB is opened and generator CB is closed automatically. Mains three phase voltage is monitored continuously. Manual Mode: Selectable from parameter settings. However user can select this mode temporarily from Auto mode thru DI. In this mode EGA-250 will be operated manually and it will ignore Mains voltage. It will only respond to START and STOP keys for Generator start and stop operation. These keys will be functional only when manual mode is active. Generator and Mains CBs will be operated externally without the control of EGA»250. Start key should be pressed until the engine reaches the threshold speed.
BenefitsFault records with date and time stamp Event records with date and time stamp Logical interlock for Mains & DG breaker for fail safe operation Measurement and display of Load current and Instantaneous load in kW Wide range of Programmable Parameters including settings of voltage, frequency, different delay times Wide array oftime circuits for start delay, stop delay, re- cooling etc Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions
Feature 9Download
Feature 10Fault records with date and time stamp
Feature 11Event records with date and time stamp
Feature 12Logical interlock for Mains & DG breaker for fail safe operation
Feature 13Measurement and display of Load current and Instantaneous load in kW
Feature 14Wide range of Programmable Parameters including settings of voltage, frequency, different delay times
Feature 15Wide array oftime circuits for start delay, stop delay, re- cooling etc
Feature 16Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions
SummaryEGA-250 is an AUTOMATIC/MANUAL Generator controller module, including protection for standby power supply. It uses a single advanced microcontroller.
C&S Subcategoryamf-relays
Full Featured AMF relay with 3 Phase CT Sensing : EGA-250RANGE Output Contacts: No. of potential output contacts:6 ; Type of contacts : Potential Input Contacts: No. of digital inputs: 5 ; No. of analog inputs: 3 FEATURES Display of 3 Phase Mains Parameters: Voltage and Frequency Display of 3 Phase Generator Parameters: Voltage, Frequency, Speed, Run Hours Metering Energy for both Mains& DG Wide range of Analog Sensor Selection All DI/DOs are programmable Presentation Benefits Contact Our Experts Download EGA-250 is a AUTOMATIC/MANUAL Generator controller module including protection for standby power supply (Generatorl DG Set). It uses single advanced micro controller chip for an easy and trouble free DG control. It is cost effective solution for AMF controlling system. If mains voltage in any phase fails (either voltage or frequency goes out of the selected range) EGA-250 initiates an automatic DG start cycle including load transfer by switching the contactors mounted in the panel. After the mains is restored the load will be automatically removed from DG and transferred to mains. DG will stop after a set cool down time. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal DG conditions are detected and displayed on LCD display and if necessary DG is stopped and hooter gets activated. Automatic Mode:This mode is selectable from parameter settings. User can toggle between Auto Mode and Manual/Remote Mode from DI also.ln this mode of operation, if the mains either fail or exceed operating limits GEN-SET is started, mains CB is opened and generator CB is closed automatically. Mains three phase voltage is monitored continuously. Manual Mode: Selectable from parameter settings. However user can select this mode temporarily from Auto mode thru DI. In this mode EGA-250 will be operated manually and it will ignore Mains voltage. It will only respond to START and STOP keys for Generator start and stop operation. These keys will be functional only when manual mode is active. Generator and Mains CBs will be operated externally without the control of EGA»250. Start key should be pressed until the engine reaches the threshold speed. Fault records with date and time stamp Event records with date and time stamp Logical interlock for Mains & DG breaker for fail safe operation Measurement and display of Load current and Instantaneous load in kW Wide range of Programmable Parameters including settings of voltage, frequency, different delay times Wide array oftime circuits for start delay, stop delay, re- cooling etc Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions <input type="hidden" name="_wpcf7cf_options" value="{"form_id":84938,"conditions":[],"settings":{"animation":"yes","animation_intime":200,"animation_outtime":200,"conditions_ui":"norma