Full Featured AMF relay with 3 Phase CT Sensing : EGA-250
| Download | Download Brochure <!-- |
|---|---|
| Feature 1 | Display of 3 Phase Mains Parameters: Voltage and Frequency |
| Feature 2 | Display of 3 Phase Generator Parameters: Voltage, Frequency, Speed, Run Hours |
| Feature 3 | Metering Energy for both Mains& DG |
| Feature 4 | Wide range of Analog Sensor Selection |
| Feature 5 | All DI/DOs are programmable |
| Feature 6 | Presentation |
| Feature 7 | Benefits |
| Feature 8 | Contact Our Experts |
| Source URL | https://cselectric.co.in/products-solutions/protectionandmeasurementdevices/amf-relays/ega-250-auto-mains-failure-relay/ |
| C&S Taxonomy Path | products-solutions > protectionandmeasurementdevices > amf-relays > ega-250-auto-mains-failure-relay |
| C&S Category | protectionandmeasurementdevices |
| Datasheet URL | https://cselectric.co.in/wp-content/uploads/2016/05/EGA-250-Catalogue.pdf |
| Presentation | EGA-250 is a AUTOMATIC/MANUAL Generator controller module including protection for standby power supply (Generatorl DG Set). It uses single advanced micro controller chip for an easy and trouble free DG control. It is cost effective solution for AMF controlling system. If mains voltage in any phase fails (either voltage or frequency goes out of the selected range) EGA-250 initiates an automatic DG start cycle including load transfer by switching the contactors mounted in the panel. After the mains is restored the load will be automatically removed from DG and transferred to mains. DG will stop after a set cool down time. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal DG conditions are detected and displayed on LCD display and if necessary DG is stopped and hooter gets activated. Automatic Mode:This mode is selectable from parameter settings. User can toggle between Auto Mode and Manual/Remote Mode from DI also.ln this mode of operation, if the mains either fail or exceed operating limits GEN-SET is started, mains CB is opened and generator CB is closed automatically. Mains three phase voltage is monitored continuously. Manual Mode: Selectable from parameter settings. However user can select this mode temporarily from Auto mode thru DI. In this mode EGA-250 will be operated manually and it will ignore Mains voltage. It will only respond to START and STOP keys for Generator start and stop operation. These keys will be functional only when manual mode is active. Generator and Mains CBs will be operated externally without the control of EGA»250. Start key should be pressed until the engine reaches the threshold speed. |
| Benefits | Fault records with date and time stamp Event records with date and time stamp Logical interlock for Mains & DG breaker for fail safe operation Measurement and display of Load current and Instantaneous load in kW Wide range of Programmable Parameters including settings of voltage, frequency, different delay times Wide array oftime circuits for start delay, stop delay, re- cooling etc Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions |
| Feature 9 | Download |
| Feature 10 | Fault records with date and time stamp |
| Feature 11 | Event records with date and time stamp |
| Feature 12 | Logical interlock for Mains & DG breaker for fail safe operation |
| Feature 13 | Measurement and display of Load current and Instantaneous load in kW |
| Feature 14 | Wide range of Programmable Parameters including settings of voltage, frequency, different delay times |
| Feature 15 | Wide array oftime circuits for start delay, stop delay, re- cooling etc |
| Feature 16 | Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions |
| Summary | EGA-250 is an AUTOMATIC/MANUAL Generator controller module, including protection for standby power supply. It uses a single advanced microcontroller. |
| C&S Subcategory | amf-relays |
| Full Featured AMF relay with 3 Phase CT Sensing : EGA-250 | RANGE Output Contacts: No. of potential output contacts:6 ; Type of contacts : Potential Input Contacts: No. of digital inputs: 5 ; No. of analog inputs: 3 FEATURES Display of 3 Phase Mains Parameters: Voltage and Frequency Display of 3 Phase Generator Parameters: Voltage, Frequency, Speed, Run Hours Metering Energy for both Mains& DG Wide range of Analog Sensor Selection All DI/DOs are programmable Presentation Benefits Contact Our Experts Download EGA-250 is a AUTOMATIC/MANUAL Generator controller module including protection for standby power supply (Generatorl DG Set). It uses single advanced micro controller chip for an easy and trouble free DG control. It is cost effective solution for AMF controlling system. If mains voltage in any phase fails (either voltage or frequency goes out of the selected range) EGA-250 initiates an automatic DG start cycle including load transfer by switching the contactors mounted in the panel. After the mains is restored the load will be automatically removed from DG and transferred to mains. DG will stop after a set cool down time. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal DG conditions are detected and displayed on LCD display and if necessary DG is stopped and hooter gets activated. Automatic Mode:This mode is selectable from parameter settings. User can toggle between Auto Mode and Manual/Remote Mode from DI also.ln this mode of operation, if the mains either fail or exceed operating limits GEN-SET is started, mains CB is opened and generator CB is closed automatically. Mains three phase voltage is monitored continuously. Manual Mode: Selectable from parameter settings. However user can select this mode temporarily from Auto mode thru DI. In this mode EGA-250 will be operated manually and it will ignore Mains voltage. It will only respond to START and STOP keys for Generator start and stop operation. These keys will be functional only when manual mode is active. Generator and Mains CBs will be operated externally without the control of EGA»250. Start key should be pressed until the engine reaches the threshold speed. Fault records with date and time stamp Event records with date and time stamp Logical interlock for Mains & DG breaker for fail safe operation Measurement and display of Load current and Instantaneous load in kW Wide range of Programmable Parameters including settings of voltage, frequency, different delay times Wide array oftime circuits for start delay, stop delay, re- cooling etc Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions <input type="hidden" name="_wpcf7cf_options" value="{"form_id":84938,"conditions":[],"settings":{"animation":"yes","animation_intime":200,"animation_outtime":200,"conditions_ui":"norma |