Isolated Phase Busduct (IPB) – MV
رقم القطعة: CS-ISOLATED-PHASE-BUSDUCT
لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.
يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.
رقم القطعة: CS-ISOLATED-PHASE-BUSDUCT
لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.
يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.
Isolated Phase Busduct (IPB) – MV
| Download | Download Brochure <!-- |
|---|---|
| Feature 1 | Presentation |
| Feature 2 | Benefits |
| Feature 3 | Contact Our Experts |
| Feature 4 | Download |
| Feature 5 | Generator Phase terminals to Generator Transformers with Tap off Connections & Generator Transformers with Tap off Connections to Unit auxiliary Transformer (UAT), Neutral Grounding Cubicles (NGC) , Excitation Transformers and Lighting arrester Voltage Transformer (LAVT) Cubicles respectively. |
| Feature 6 | Generator Phase terminals to Generator Circuit Breakers ( GCB) & Generator Circuit Breakers ( GCB) & to Transformer with Tap off Connections to Unit auxiliary Transformer (UAT), Neutral Grounding Cubicles (NGC) , Excitation Transformers and Lighting arrester Voltage Transformer (LAVT) Cubicles respectively. |
| Feature 7 | Generator Transformer Delta formation for three single phase Transformers. |
| Feature 8 | Excellent Shielding under short circuit Conditions. Design facilitates the effect of self-centering during short circuit forces and hence uniform dielectric is maintained. |
|---|---|
| Source URL | https://cselectric.co.in/products-solutions/power-busbars/metal-enclosed-busbar-isobar/isolated-phase-busduct/ |
| C&S Taxonomy Path | products-solutions > power-busbars > metal-enclosed-busbar-isobar > isolated-phase-busduct |
| C&S Category | power-busbars |
| Presentation | C&S Offers Isolated Phase Busduct (IPB) comes under “Isobar Range” for Medium Voltage Power Busbar Solutions from 11KV-38KV & 100A-30,000A. Application Isolated Phase Busduct (IPB) finds application in Power Generating Units between Generator Phase terminals to Generator Transformers with Tap off Connections & Generator Transformers with Tap off Connections to Unit auxiliary Transformer (UAT), Neutral Grounding Cubicles (NGC) , Excitation Transformers and Lighting arrester Voltage Transformer (LAVT) Cubicles respectively. Generator Phase terminals to Generator Circuit Breakers ( GCB) & Generator Circuit Breakers ( GCB) & to Transformer with Tap off Connections to Unit auxiliary Transformer (UAT), Neutral Grounding Cubicles (NGC) , Excitation Transformers and Lighting arrester Voltage Transformer (LAVT) Cubicles respectively. Generator Transformer Delta formation for three single phase Transformers. Above Applications will find Power Transmission solutions in following segments Power generating stations (Thermal, Hydro, Gas based, Nuclear & Combined cycle) The Power Busbar Division of C&S has been continuously addressing the market needs over past four decades in various applications. With the acquisition of Eta-com having specialization in Cast Resin Insulated Busway, C&S Power Busbar division has emerged as “Global Power Busbar Specialist.” With the combination of Supreme range, vast experience in R&D, engineering, state of art manufacturing plants, in-house testing facilities, and strong project management is aimed to provide one stop solution for all your Power Busbar needs. |
| Benefits | Excellent Shielding under short circuit Conditions. Design facilitates the effect of self-centering during short circuit forces and hence uniform dielectric is maintained. Conductor design eliminates Corona Discharge. Skin Effects factor is minimum and very accurate by virtue of Circular / Tubular Conductors. Symmetry simplifies calculations and precision. Uniform Heat dissipation over entire Surfaces. Three Insulator design helps To eliminates the effect of Cantilever forces. For easy Maintenance as Insulators can be easily removed from Outside. Busbars to get aligned at its magnetic centre and therefore uniform dielectric strength is maintained between busbars and enclosure by virtue of position of Insulators at 120 Degree apart. By providing better stability of the entire system and enhanced performance Complies to Seismic compliance to zone V. Isolated phase busduct can be equipped with anti-condensation equipment Viz. Air pressurization/Hot air blowing / space heater. Conformity to International standards. |
| Feature 9 | Conductor design eliminates Corona Discharge. |
| Feature 10 | Skin Effects factor is minimum and very accurate by virtue of Circular / Tubular Conductors. |
| Feature 11 | Symmetry simplifies calculations and precision. |
| Feature 12 | Uniform Heat dissipation over entire Surfaces. |
| Feature 13 | Three Insulator design helps To eliminates the effect of Cantilever forces. |
| Feature 14 | For easy Maintenance as Insulators can be easily removed from Outside. |
| Feature 15 | Busbars to get aligned at its magnetic centre and therefore uniform dielectric strength is maintained between busbars and enclosure by virtue of position of Insulators at 120 Degree apart. |
| Feature 16 | By providing better stability of the entire system and enhanced performance |
| Summary | C&S Electric offers a highly-efficient isobar range of isolated phase busduct from 11 kV to 38 kV & current rating of up to 30000A. Explore the feature details. |
| C&S Subcategory | metal-enclosed-busbar-isobar |
| Compliance of standard | IS 8084 / IEEE C37.23 / IEC 62271 |
| Rated Operational Voltage (Ue) | 11kV – 38kV |
| Rated Impulse Withstand Voltage (Uimp) | 75kV – 170kV (1.2/50 µSec) |
| Enclosure Material | Aluminium Alloy |
| Degree of Protection | IP 55 / IP 65 |
| Rated Continuous Current | 100A-30,000A |
| Conductor | Aluminium * |
| Rated Short Time Withstand Current (Icw) | 80KA to 400kA (for 1 Sec.) |
| Isolated Phase Busduct (IPB) – MV | Compliance of standard IS 8084 / IEEE C37.23 / IEC 62271 Rated Continuous Current 100A-30,000A Conductor Aluminium * Rated Operational Voltage (Ue) 11kV – 38kV Rated Short Time Withstand Current (Icw) 80KA to 400kA (for 1 Sec.) Enclosure Material Aluminium Alloy Rated Impulse Withstand Voltage (Uimp) 75kV – 170kV (1.2/50 µSec) Degree of Protection IP 55 / IP 65 *Copper conductors available on request. Presentation Benefits Contact Our Experts Download C&S Offers Isolated Phase Busduct (IPB) comes under “Isobar Range” for Medium Voltage Power Busbar Solutions from 11KV-38KV & 100A-30,000A. Application Isolated Phase Busduct (IPB) finds application in Power Generating Units between Generator Phase terminals to Generator Transformers with Tap off Connections & Generator Transformers with Tap off Connections to Unit auxiliary Transformer (UAT), Neutral Grounding Cubicles (NGC) , Excitation Transformers and Lighting arrester Voltage Transformer (LAVT) Cubicles respectively. Generator Phase terminals to Generator Circuit Breakers ( GCB) & Generator Circuit Breakers ( GCB) & to Transformer with Tap off Connections to Unit auxiliary Transformer (UAT), Neutral Grounding Cubicles (NGC) , Excitation Transformers and Lighting arrester Voltage Transformer (LAVT) Cubicles respectively. Generator Transformer Delta formation for three single phase Transformers. Above Applications will find Power Transmission solutions in following segments Power generating stations (Thermal, Hydro, Gas based, Nuclear & Combined cycle) The Power Busbar Division of C&S has been continuously addressing the market needs over past four decades in various applications. With the acquisition of Eta-com having specialization in Cast Resin Insulated Busway, C&S Power Busbar division has emerged as “Global Power Busbar Specialist.” With the combination of Supreme range, vast experience in R&D, engineering, state of art manufacturing plants, in-house testing facilities, and strong project management is aimed to provide one stop solution for all your Power Busbar needs. Excellent Shielding under short circuit Conditions. Design facilitates the effect of self-centering during short circuit forces and hence uniform dielectric is maintained. Conductor design eliminates Corona Discharge. Skin Effects factor is minimum and very accurate by virtue of Circular / Tubular Conductors. Symmetry simplifies calculations and precision. Uniform Heat dissipation over entire Surfaces. Three Insulator design helps To eliminates the effect of Cantilever forces. For easy Maintenance as Insulators can be easily removed from Outside. Busbars to get aligned at its magnetic centre and therefore uniform dielectric strength is maintained between busbars and enclosure by virtue of position of Insulators at 120 Degree apart. By providing better stability of the entire system and enhanced performance Complies to Seismic compliance to zone V. Isolated phase busduct can be equipped with anti-condensation equipment Viz. Air pressurization/Hot air blowing / space heater. Conformity to International standards. |
| Datasheet URL | https://cselectric.co.in/wp-content/uploads/2020/01/Isobar-Catalog_2020.pdf |