ABB

OVR T2 40-440 P QS

رقم القطعة: 2CTB803871R1200

لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.

يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.

الوصف

جهاز حماية من الجهد العابر، فئة II OVR T2 40-440 P QS، أحادي القطب

المواصفات

EPLAN Data9AAC183885_EPLAN
Product Net Width17.8 mm
Product Net Depth / Length58 mm
Product Net Height88 mm
Product Net Weight0.12 kg
Number of Poles1P
StandardsIEC 61643-11 / EN 61643-11
Degree of ProtectionIP20
كل المواصفات (63)
Width in Number of Modular Spacings1
Maximum Operating Altitude PermissibleWithout Derating 5000
REACH Declaration9AKK107492A1906
RoHS Declaration9AKK108466A4410
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
EcoSolutions Profile9AKK108472A3406
Environmental Product Declaration - EPD9AKK108472A1711
Declaration of Conformity - CE9AKK108466A4410
Package Level 1 Unitsbox 1 piece
Package Level 1 Gross Weight145 g
Object Classification Code141DEC
ETIM 9EC000941 - Surge protection device for power supply systems
eClassV11.0 : 27130805
UNSPSC39121610
E-Number (Norway)1672331
Source URLhttps://new.abb.com/products/2CTB803871R1200/ovr-t2-40-440-p-qs
ABB Taxonomy PathLow Voltage Products and Systems > Modular DIN Rail Products > Surge Protective Devices SPDs > Surge Protective Devices SPD Class II
ABB Classification IDs9AAC910006, 9AAC100512, 9AAC183885
Suitable ForTo protect the systems against the transient overvoltage (lightning)
ETIM 10EC000941 - Surge protection device for power supply systems
Rated Service Short-Circuit Breaking Capacity (Ics)100 kA
Number of Protected Poles1
Rated Voltage (Ur)230 V AC
Fuse Size1 modular spacing
Mounting TypeDIN-Rail
Product TypeQS
VersionPlug-in
REACH InformationFalse - does not contain substances > 0.1 mass percentage
RoHS Date20230707
REACH Date20231212
Declaration2CTC432056G1701
Carbon Footprint (Full Lifecycle)11.058672 kg CO₂ eq
Voltage Protection Level ( Up)1.8 kV
Options ProvidedResidential, commercial building.
Type of Low Voltage Distribution SystemTT
Nominal AC Voltage of the System (Uo)400 / 690 V
Maximum Continuous Operating Voltage (Uc)(L-PE) 440 V
Temporary Overvoltage Test Value (UT)581 V
Discharge CurrentNominal (8 / 20 µs) 20 kA
Impulse CurrentI (imp, 10 / 350 µs, L-N) 2 kA
Short Circuit Withstand Icc100 kA
Arrester ClassII
Number of Conductors1
Transmission StandardOptic
Auxiliary Circuit LoadMinimum -
Preventive Maintenance FeatureNo
Status IndicatorYes
Cross-Section (A<subMaximum Conductor Solid-Stranded 25 mm²
Data Sheet, Technical Information2CTC432212D0201
Instructions and Manuals2CTC432097M1701
CB Certificate2CTC432024G1701
CQC Certificate9AKK107680A1974
Mechanical Drawings2CTC800021F0100.pdf

السعر عند الطلب

اطلب عرض سعر