Eaton XC Modular PLC
رقم القطعة: 290446
لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.
يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.


رقم القطعة: 290446
لا يعرض أي بائع سعرًا لهذا المنتج بعد. أرسل طلبك وسنعود إليك بأفضل عرض.
يكتمل الطلب في تطبيق Ohmva بعد تسجيل الدخول.
Eaton XC Modular PLC
| Ambient operating temperature - max | 55 °C |
|---|---|
| Ambient operating temperature - min | 0 °C |
| Ambient storage temperature - max | 70 °C |
| Ambient storage temperature - min | -25 °C |
| Functions | Overvoltage protection Additional program memory possible |
| Catalog Number | 290446 |
| Model Code | XC-CPU121-2C256K |
| Product Length/Depth | 100 mm |
| Product Height | 100 mm |
|---|---|
| Product Width | 60 mm |
| Product Weight | 0.195 kg |
| Certifications | CE EN 50178 CSA Class No.: 2252-01 UL File No.: E135462 CSA IEC/EN 61131-2 UL Category Control No.: NRAQ CSA-C22.2 No. 0-M UL CSA File No.: 012528 CSA-C22.2 No. 142-M UL508 EAC |
| Source URL | https://www.eaton.com/gb/en-gb/skuPage.290446.html |
| Catalog Notes | can be locally expandable with I/O module XIO-EXT-121-1 |
| Features | Asynchronous, cyclic, acyclic PDO types (CAN1/CAN2 interface) Expandable with XC-CPU121 expansions Mains overvoltage protection (power supply) Expandable with XI/OC expansions Mains filter (power supply) |
| Type | Modular PLC XC-CPU121 |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Meets the product standard's requirements. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Degree of protection | IP20 |
| Mounting method | Rail mounting possible Wall mounting/direct mounting |
| Number of modules | 126 (CAN1/CAN2 interface) |
| Model | Modular |
| Mounting position | Horizontal |
| Shock resistance | 15 g, Mechanical, Shock duration 11 ms |
| Vibration resistance | 5 - 9 Hz, Amplitude 3.5 mm 9 - 150 Hz, 1 g constant acceleration |
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0 W |
| Rated operational current for specified heat dissipation (In) | 0 A |
| Static heat dissipation, non-current-dependent Pvs | 6 W |
| Connection type | Spring-loaded terminal block, 6-pole, COM2, CAN1, CAN2 interface Spring-loaded terminal block RJ45, Ethernet |
| Pollution degree | 2 |
| Rated insulation voltage (Ui) | 500 V |
| Overvoltage category | II |
| Terminal capacity | 0.14 - 0.5 mm² AWG 28-20 |
| Voltage type | DC |
| Power consumption | Max 1.44 W |
| Rated operational current (Ie) | 0 A |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Memory capacity | 256 kByte |
| Memory type | RAM |
| Memory | 244 kByte Program data code, optional extension 4 kByte Input Memory 4 kByte Output Memory 8 kByte Retain Memory 16 kByte Marker Memory 256 kByte (User memory) 256 kByte Program memory code, optional extension |
| Power loss | 6 W |
| Relative humidity | 10 - 95 % (non-condensing) |
| Protocol | PROFIBUS SUCONET MODBUS CAN Other bus systems |
| Input voltage | 24 V DC (Power supply) 24 V DC (Power supply of local inputs/outputs) |
| Air pressure | 795 - 1080 hPa (operation) |
| Bus termination | Selectable for CAN1/CAN2, first and last station External, for RS485 |
| Number of channels | 0 |
| Safety performance level (EN ISO 13849-1) | None |
| SIL (IEC 61508) | None |
| Number of HW-interfaces (industrial ethernet) | 0 |
| Number of HW-interfaces (other) | 1 |
| Number of HW-interfaces (parallel) | 0 |
| Number of HW-interfaces (RS-232) | 1 |
| Number of HW-interfaces (RS-422) | 0 |
| Number of HW-interfaces (RS-485) | 1 |
| Number of HW-interfaces (USB) | 0 |
| Number of HW-interfaces (wireless) | 0 |
| Number of interfaces (PROFINET) | 0 |
| Number of outputs (analog) | 0 |
| Duty factor | 100 %, Digital outputs |
| Supply voltage | 20.4 - 28.8 V DC |
| Emitted interference | According to IEC/EN 61000-6-4 |
| Interference immunity | According to EN 61000-6-2 |
| Protection against polarity reversal | Yes, for AS-Interface Yes |
| Number of inputs (analog) | 0 |
| Cycle time | < 0.3 ms, for 1 k of instructions (Bit, Byte), memory |
| Number of outputs (digital) | 8 |
| Data transfer rate | 19.2 kBit/s, Serial interface (RS232) without handshake lines, Transparent mode 1.2 kBit/s, Serial interface (RS232) without handshake lines, Transparent mode 0.3 kBit/s, Serial interface (RS232) without handshake lines, Transparent mode 0.6 kBit/s, Serial interface (RS232) without handshake lines, Transparent mode 19.2 kBit/s, Serial interface (RS232) without handshake lines, Programming, Character format: 8 data bits, no parity, 1 stop bit 19.2 kBit/s, COM2 (RS232/RS485) without handshake lines, Transparent mode, Set through function blocks 10 - 500 kBit/s, CAN1/CAN2 1.2 kBit/s, COM2 (RS232/RS485) without handshake lines, Transparent mode, Set through function blocks 0.3 kBit/s, COM2 (RS232/RS485) without handshake lines, Transparent mode, Set through function blocks 0.6 kBit/s, COM2 (RS232/RS485) without handshake lines, Transparent mode, Set through function blocks |
| Number of relay outputs | 0 |
| Residual ripple | ≤ 5 % |
| Inrush current | No limitation (limited only by upstream 24 V DC power supply unit) |
| Input current | 60 mA |
| Processor | Infineon XC161 |
| Number of time switches - max | 1000 |
| Processing time | 0.5 ms |
| Repetition rate | 1 s |
| Supply voltage at AC, 50 Hz - max | 0 VAC |
| Supply voltage at AC, 50 Hz - min | 0 VAC |
| Supply voltage at AC, 60 Hz - max | 0 VAC |
| Supply voltage at AC, 60 Hz - min | 0 VAC |
| Supply voltage at DC - max | 28.8 VDC |
| Supply voltage at DC - min | 20.4 VDC |
| Heat dissipation details | Without local I/O |
| Signal range | 19.2 - 30 V DC (Power supply of local inputs/outputs, note polarity) |
| Interfaces | RS485/RS232 (built-in) RS232 (built-in) 2 x CANopen® (built-in) |
| System accessory | Yes |
| Utilization factor | 0 (Inductive load to EN 60947-5-1, Without external suppressor circuit, T0.95 = 1 ms, R = 48 Ω, L = 16 mH) |
| Potential isolation | CAN1/CAN2 interface: no Power supply of local inputs/outputs (24 V/0 V) against CPU voltage: yes |
| Number of inputs (digital) | 18 |
| Voltage dips | 10 ms |
| Backup time | > 72 hours (time at zero voltage) |
| Terminal capacity (AWG) | 28 - 20 |
| Character formats | 8E1, 8O1, 8N1, 8N2, 7E2, 7O2, 7N2, 7E1, Serial interface (RS232) without handshake lines, transparent mode 8E1, 8O1, 8N1, 8N2, 7E2, 7O2, 7N2, 7E1, COM2 (RS232/RS485) without handshake lines, transparent mode, set through function blocks |
| Rapid counter inputs | 190 bytes in each block |
| Number of bytes | 190 bytes |
| Terminal capacity (solid/stranded) | 0.14 - 1 mm² |
| Terminal capacity (solid/stranded AWG) | 28 - 18 |